Metric Catheters with Metric (Straight)

Purpose
Tracheobronchial suctioning of the lower airways
Features
- Atraumatic rounded distal eyes
- Integrated, ergonomic connector
- Frosted surface facilitates introduction through endotracheal tube
- Marks and numbers at each cm starting 5 cm from the distal end
Mully
- Less traumatic compared to other designs
- Higher efficiency at lower vacuum level
- 2 small relieving eyes reduce risk of blockage
- Hardness: shore A 78
- Recommended for all suctioning
Optimal
Same features as Mully - but softer
- Hardness: Shore A 64
Vacutip
- Transparent connector for easy observation of secretions
- Color-coded for easy identification of CH
- No contamination of finger
- Maximum vacuum reduction ensures suctioning only when required
- Decreased removal of residual air
Metric-Marking
- Increased safety for accurate positioning of the suction catheter
- Allows standardization between members of staff
- Highly recommended for neonatal use
Precautions
- Suction catheters are not advanced more than 1 cm beyond the end of the endotracheal tube
Specifications
Vacutip: |
Funnel: |
Catheter: |
| Styrene acrylonitrile |
Polivynil Chloride |
Polivinyl chloride |
Hardness: See diagram below
Metric-marking
285 + 290 mm = 5-20 cm
465 + 535 mm + 5-40 cm
Single peel-packed
Sterilized by ethylene oxide
Suction Catheters with Vacutip (Straight)

Purpose
Tracheobronchial suctioning of the lower airways
Features
- Atroamatic, rounded distal eyes
- Integrated ergonomic connector
- Frosted surface facilitates introduction through endotracheal tube
Mully
- Less traumatic compared to other designs
- Higher efficiency at lower vacuum level
- 2 small relieving eyes reduce risk of blockage
- Hardness: shore A 78
- Recommended for all suctioning
Vacutip
- Transparent connector for easy observation of secretions
- Color-coded for easy identification of CH
- No contamination of finger
- Maximum vacuum reduction ensures suctioning only when required
- Decreased removal of residual air
Optimal
- Same features as Mully - but softer
- Hardness: Shore A 64
Specifications
Vacutip
Styrene acrylonitrile
Catheter
Polyvinyl chloride
Hardness: See diagram below
Single peel-packed
Sterilized by ethylene oxide
Suction Catheters with Vacutip (Coude)

Purpose
Tracheobronchial suctioning of the lower airways. Espcially for introducion into the left bronchius.
Vacutip
- Transparent connector for easy observation of secretions
- Color-coded for easy identification of CH
- No contamination of finger
- Maximum vacuum reduction ensures suctioning only when required
- Decreased removal of residual air
Features
- Increases the rate of successful introduction into the left bronchus
- Atraumatic, rounded, distal eye
- Frosted surface facilitates introduction through endotracheal tube
- Integrated ergonomic connector
Mully
- Less traumatic compared to other designs
- Higher efficiency at lower vacuum level
- 2 small relieving eyes reduce risk of blockage
- Hardness: shore A 78
- Recommended for all suctioning
Vacutip
- Transparent connector for easy observation of secretions
- Color-coded for easy identification of CH
- No contamination of finger
- Maximum vacuum reduction ensures suctioning only when required
- Decreased removal of residual air
Specifications
Vacutip
Styrene acrylonitrile
Catheter
Polyvinyl chloride, medical grade
Hardness: See diagram below
Single peel-packed
Sterilized by ethylene oxide
Suction Catheters with Fingertip (Straight)

Purpose
Tracheobronchial suctioning of the lower airways.
Features
- Atraumatic, rounded, distal eye
- Frosted surface facilitates introduction through endotracheal tube
- Integrated vacuum control for vacuum reduction
- Color-coded vacuum control for easy identification of CH
Mully
- Less traumatic compared to other designs
- Higher efficiency at lower vacuum level
- 2 mall relieving eyes reduce risk of blockage
- Hardness: Shore A 78
- Recommended for all suctioning
Specifications
Fingertip
Polyvinyl chloride
Catheter
Polyvinyl chloride, medical grade
Hardness: See diagram below
Single peel-packed
Sterilized by ethylene oxide
Suction Catheters with Funnel (Straight)

Purpose
Tracheobronchial suctioning of the lower airways.
Features
- Atraumatic, rounded, distal eye
- Frosted surface facilitates introduction through endotracheal tube
- Recommended only for use with equipment permitting separate vacuum control
- Color-coded funnel for easy identification of CH
Mully
- Less traumatic compared to other designs
- Higher efficiency at lower vacuum level
- 2 small relieving eyes reduce risk of blockage
- Hardness: Shore A 78
- Recommended for all suctioning
Optimal
Same features as Mully - but softer
Hardness: Shore A 64
Specifications
Polyvinyl chloride, medical grade
Hardness: See diagram below
Single peel-packed
Sterilized by ethylene oxide
Suction Catheters with Funnel (Coude)

Purpose
Trachobronchial suctioning of the lower airways. Especially for introduction into the left bronchus.
Features
- Increase the rate of successful introduction into the left bronchus
- Atruamatic, rounded, distal eye
- Frosted surface facilitates introduction through endotracheal tube
- Recommended only for use with equipment permitting separate vacuum control
- Color-coded funnel for easy identification of CH
Mully
- Less traumatic compared to other designs
- Higher efficiency at lower vacuum level
- 2 small relieving eyes reduce risk of blockage
- Hardness: Shore A 78
- Recommended for all suctioning
Optimal
Same features as Mully - but softer
Hardness: Shore A 64
Specifications
Polyvinyl chloride, medical grade
Hardness: See diagram below
Single peel-packed
Sterilized by ethylene oxide